05:18 — 05:43 Station GN802:
CTD profile with rosette sampler and GoFIlo for metals.
RA: Cs-137: 150 L.
W&S 07:00: Bft. 4-5, 200°, 999 hPa, cloudy, Tw= 18.0 °C.
09:16 — 09:43 Station GN803:
Secchi, CTD profile with rosette sampler and GoFlo for metals.
RA: Cs-137: 150 L.
11:35 — 11:48 Station GN804:
Secchi, CTD profile with rosette sampler and GoFlo for metals.
RA: Cs-137: 150 L, Sr-90: 2x35 L, Pu: 100 L, H-3: 1 L.
12:00: Bft. 4, 200°, 1002 hPa, cloudy, Tw= 18.1 °C.
14:18 — 14:30 Station GN805:
Secchi, CTD profile with rosette sampler and GoFlo for metals.
RA: Cs-137: 150 L.
W&S 21:00: Bft. 6, 220°, 1001 hPa, cloudy and lightning, Tw = 18.0 °C.
21:16 — 21:35 Station GN806:
Secchi, CTD profile with rosette sampler and GoFlo for metals.
RA: Cs-137: 150 L.
Wednesday, August 13", 2014
01:31 — 02:07 Station GN807:
CTD profile with rosette sampler and GoFIlo for metals.
RA: Cs-137: 150 L.
05:58 — 10:45 Station GN808:
Secchi, CTD profile with rosette sampler and GoFlo for metals.
RA: Cs-137: 150 L, Sr-90: 2x35 L, Pu: 100 L, H-3: 1 L.
270-I-samplers for radioactivity at 50, 100, 250, 500 and 668 m depth, however, only
the first two samplers closed properly due to strong tidal currents.
W&S 09:30: Bft. 5, 190°, 1000 hPa, cloudy, Tw= 19.1 °C.
W&S 16:30: Bft. 3-4, 180°, 998 hPa, covered, Tw = 18.0 °C.
16:48 — 18:20 Station GNO040 (Skagerrak):
Secchi depth, CTD profile with rosette sampler and GoFlo for metals.
RA: Cs-137: 150 L, Sr-90: 2x35 L, Pu: 100 L, H-3: 1 L.
SF> 19:02: Start SF profile 18, GN040 >GN041.
SF«< 19:43: End of SF profile 18 due to communication problems, possibly due to water in
the termination.
W&S 20:00: Bft. 2, 210°, 998 hPa. cloudy, rain shower, Tw= 19.1 -C.
16