accessibility__skip_menu__jump_to_main

Volltext : Meteor-Reise Nr. 71, Norwegen - Grönlandsee (BSH-Berichte, Nr. 12)

6

All  water  samples  are  analyzed  unfiltered.  To  determine  the  salinity,  a  water  sample  is  taken
from  each  sampler.
134 Cs  and  l37 C$
Caesium  is  coprecipitated  with  potassium  hexanitrocobaltate  from  50  -  500  1  of  sea  water,
purified  and  finally  precipitated  as  caesium  iodobismuthate.  The  chemical  yield  is  determined
gravimetrically,  the  activity  is  measured  in  a  Low-Level-Beta-Counter  [16].  Before  analysing
samples  of  more  than  200  1,  l37 Cs  is  extracted  from  the  sea  water  by  passing  a  potassium
hexacyanocobaltate-(II)-ferrate(II)  adsorbend  [2].  The  adsorbend  is  then  measured  gamma-spec  -
troscopically  to  determine  the  137 Cs  activity  or  the  137 Cs/ l34 Cs  activity  ratio.
!^Sr
To  determine  "Sr,  the  activity  of  its  decay  product  is  isolated  by  fluid-fluid-extraction  from
up  to  200  1  of  water.  Its  oxide  is  then  measured  using  a  Low-Level-Anticoincidence-Beta-Counter
  [3].  To  improve  the  method's  detection  limit  in  case  of  deep  water  samples,  thorium-234
  is  first  separated  by  Zr 3 (Po 4 ) 4  coprecipitation.
Transuranics
239+240 Pu,  238 Pu  and  241 Am  are  extracted  from  200  1  sea  water  samples  after  Murray  and  Statham.
The  samples  are  electroplated  separately  for  Pu  and  Am  and  are  measured  alpha-spectroscopically
  [12].  242 Pu  and  243 Am  are  used  as  yield  tracers.  241 Pu  is  determined  on  the  basis  of  the  421 Am
activity  ascent  after  a  few  years.
Tritium
After  vacuum  distillation,  325  ml  water  samples  are  enriched,  with  a  yield  of  almost  80%,  in
electrolytic  cells  like  those  of  Ôstlund  [14],  equipped  with  electrodes  of  stainless  steel  (anode)
and  phosphated  iron  (cathode)  after  Zutshi  [18].  5  ml  of  the  concentrate  is  decomposed  by  manganese ­
  in  an  autoclave.  The  resulting  gas  sample  is  measured  in  a  Low-Level-Intemal-Gas
Counter  [11].  The  limit  of  detection  of  this  method  is  0,01  Bq/1.

Literatur
[1]  Borcherding,  I.  and  H.  Nies,  1986:
An  Improved  Method  of  the  Determination  of  ^Sr  in  Large  Samples  of  Seawater.
Journal  of  Radioanalytical  and  Nuclear  Chemistry,  Articles,  Vol.  98,  No.  1,  127-131
[2]  Eicke,  H.-F.,  1974:
Eine  Methode  zur  Anreicherung  und  Bestimmung  sehr  geringer  Gehalte  von  l37 Cs  im
ozeanischen  Tiefenwasser.  Dt.  hydrogr.  Z.,  27,  20-26
[3]  Fukai,  R.,  G.  Statham  and  K.  Asari,  1976:
A  Rapid  Method  for  ‘"Sr  Analysis  by  HDEHP  Solvent  Extraction  Application  to  Large
Volume  Water  Samples.  Rapp.  Comm.  int.  Mer  Médit.,  23  (7),  149-150
            
Waiting...

Nutzerhinweis

Sehr geehrte Benutzerin, sehr geehrter Benutzer,

aufgrund der aktuellen Entwicklungen in der Webtechnologie, die im Goobi viewer verwendet wird, unterstützt die Software den von Ihnen verwendeten Browser nicht mehr.

Bitte benutzen Sie einen der folgenden Browser, um diese Seite korrekt darstellen zu können.

Vielen Dank für Ihr Verständnis.