accessibility__skip_menu__jump_to_main

Full text: Environmental impacts of exhaust gas cleaning systems for reduction of SOx on ships – analysis of status quo

/EXTE Environmental Impacts of Exhaust Gas Cleaning Systems for Reduction of SOx on Ships — Analysis of status quo 
zeport compiled within the framework of the project ImpEx 
Parameter 
Zinc (ug/L) 
| cc. [53] 
BSH [5] | IvLIT 
2133 
2-133(df) 
82 
55 
51 (df) 
Open loop 
CESA | NORW | Dru[11 I cowıı [1] 
[201 [119 
<10- | 11 
2.000 
BSH [3] l ıvL[21 
76 — 240 
23 — 208 
{dP} 
<70 
Closed loop 
CESA[4] | cowı [1] 
40 —2 400 
160 —- 420 
Sources: BSH, Schmolke et al. (2020): IVL, Magnusson et al. (2018); CCL, Carnival Copr. & plc and DNV GL (2019): CESA, EGCSA and Euroshore (2018): NORW, Ushakov et al. (2019); DTU, Koski et al. 
(2017); COWI, Kjelholt et al. (2012). 
Legends: [n], number of sampled ships; df, dissolved fraction; SS, suspended solids; <LOD, below limit of detection; NA, not analysed/reported; NAP, naphthalene; PHE, Phenanthrene; B[a]P, 
benzo[alpyrene . 
i) Average-30 values Post-DeSOx. Samples taken before any dilution for pH adjustment. 
ii) Sum of average-30 values of single PAHs. 
iii) Values shown in this table were calculated, for better comparability, from the originally sulphate measurements (SO4?- mg/L) reported in Table A-4 of that study 
iv) Values shown in this table were calculated, for better comparability, from the originally reported values in NO3-N and NO„-N, respectively, from that study. 
v) Instead, total nitrogen was measured. Results range between 0.22 — 0.56 mg N/L in OL and 86 - 120 mg N/L in CL. 
vi) Measured parameter was Hydrocarbon Oil Index (HOl) according to standard ISO 9377-2. 
vii) Reported value corresponds to the sum of all aliphatic (Cs-Cao) and aromatic (C10-C36) fractions measured, in the report called Total Hydrocarbons. 
viii) Reported value corresponds to the sum of benzene —- C3s, in the report called Total Hydrocarbons. 
ix) Samples taken before any dilution for pH adjustment. 
x) Reported value corresponds to the sum of hydrocarbon fractions (C10-Cao). 
xi) Values taken from the Table 6 column “Washwater before discharge” — “IMO (no dilution)” of the referenced article. Samples were taken after water treatment (particle removal) and prior 
any dilution. 