Cruise Report, RV ATAIR, Cruise 067I033-1, Bremerhaven – Thybor?n – Aberdeen, 23 Jul – 15 Aug 2024 25
5.8 Water Sampling with respect to Dissolved Inorganic Carbon &
Alkalinity
Samples for total alkalinity (AT) and total inorganic carbon (CT) were taken at 2 to 8 depth levels
per profile. The samples were collected from the Niskin bottles using silicone tubing. For AT
and CT, unfiltered water samples were collected in 300 mL BOD bottles (avoiding gas ex-
change), stabilized with 300 ?L of saturated mercury chloride solution (HgCl2), and stored un-
der dark conditions until further analysis in the home laboratory (Helmholtz-Zentrum Hereon)
located in Geesthacht. In total, 501 samples for AT and CT analysis were taken.
Figure 5.10. Distribution of stations carried out during cruise 067I033-1 with alkalinity and dissolved
inorganic carbon sampling (red dots).
5.9 Water sampling with respect to Trace Metal, Mercury, Nutrient &
Lead Analysis
Samples for dissolved trace metal analysis were taken at 105 stations at 10 m water depths
using one of the two available trace-metal clean Go-Flo sampling bottles. Water samples were
collected in acid-cleaned 50 mL DigiTubes and stored cold until filtration. The samples were
filtered onboard through 0.45 ?m PTFE acid-cleaned DigiFilters. Filtration was carried out in a