ä tT Fallbeispiel Prüfung aktueller Nav.-Geräte
BUNDESAMT FÜR
SEESCHIFFFAHRT
UND
HYDROCRAPHIE
Prüfung AIlS-Geräte
14.6.2.5 GNSS position mismatch
14.6.3.5.1 Method of measurement
Set up standard test enviranment and operate EUT with valid internal position avallable and
using valıd external position.
a) Apply an external position with an offset of more than 100 m to the internal position for
3 min. Then modify external position 10 an offset of less than 100 m to the Internal
POSILON.
Maodify the external position to an offset of more than 100 m to the internal position for
more than 1 h_
cz} Then modify external position to an offset of less than 100 m to the internal position.
14.6.3.5.2 Required results
Check that
i}
a) no alarm sentence ALR Is output,
b) an alarm sentence ALR with alarm ID BO9 with status active Is output 15 min after the
modification of the position,
2} the alarm sentence ALR with alarm ID 009 with status inactiive is output/
Quelle: Standard IEC 61993-2