Volltext : Numerical implementation and oceanographic application of the thermodynamic potentials of liquid water, water vapour, ice, seawater and humid air : Part 1: background and equations

R.  Feistel  et  al.:  Oceanographic  application  and  numerical  implementation  of  TEOS-IO:  Part  1

661

www.ocean-sci.net/6/633/2010/

Ocean  Sci.,  6,  633-677,  2010

be  unstable  if  thermodynamic  stability  criteria  such  as  positive ­
  compressibility  are  violated.  (Independent  of  any  simultaneous ­
  existence  of  other  phases,  a  negative  compressibility ­
  would  amplify  any  pressure-density  fluctuation,  causing
the  fluid  to  collapse.)  The  boundary  between  metastable  and
unstable  existence  is  regarded  as  the  spinodal  line  beyond
which  the  phase  can  no  longer  stably  and  homogeneously
exist.
Since  it  is  practically  impossible  to  measure  thermodynamic ­
  properties  on  or  beyond  the  spinodal,  its  location
in  the  phase  diagram  is  not  exactly  known  from  empirical
equations  of  state.  Even  though  the  IAPWS-95  formulation
extrapolates  well  into  the  metastable  regions  (Wagner  and
Pilli),  2002;  Feistel  et  al.,  2008),  with  increasing  distance
from  the  saturation  line  the  values  computed  from  the
Helmholtz  function  outside  its  validity  range  will  become
unreliable.  This  turns  out  not  to  be  a  major  issue  for  determination ­
  of  the  seawater  Gibbs  function  since  we  require
only  relatively  small  excursions  into  the  metastable  regions
to  deal  with  the  effects  of  shifted  phase  transition  boundaries
in  the  presence  of  sea  salt.
Panels  a  and  b  of  Fig.  Al  indicate  the  initializations  used  in
the  library  for  our  iterative  solutions  for  the  liquid  and  vapour
phases,  respectively.  Figure  A2  provides  additional  information ­
  regarding  the  industrial  formulation  IF-97  (IAPWS,
2007;  Wagner  and  Kretzschmar,  2008)  referred  to  in  Fig.  Al.
Starting  in  either  fluid  state  at  a  point  near  CP  located
along  the  saturation  line  joining  TP  and  CP,  we  may  circumscribe ­
  the  critical  point  along  a  closed  T—P  path.  Along
any  such  curve,  the  properties  change  only  gradually;  nothing ­
  like  a  transition  point  between  liquid  and  vapour  is  encountered. ­
  Since,  for  numerical  purposes,  we  distinguish  between ­
  the  Gibbs  functions  of  liquid,  Eq.  (Al),  and  vapour,
Eq.  (A2),  we  need  to  specify  such  a  transition  point  for  technical ­
  rather  than  for  physical  reasons.  Here  we  define  the
Gibbs  functions  Eqs.  (Al)  and  (A2)  to  be  different  at  subcritical
  conditions  (T<Tq  and  P<Pq)  and  to  be  identical  at
supercritical  conditions  (T>Tc  or  P>Pc)■  The  critical  temperature ­
  of  water  is  7c=647.096K  and  the  critical  density
is  pc=322kgm -3  (IAPWS,  2009a);  the  critical  pressure  follows ­
  from  Eq.  (4.1)  to  be  Pc=22.064MPa.  In  order  to  cover
metastable  states  of  liquid  water  as  required  in  the  regions  of
vapour-pressure  lowering  or  freezing-point  lowering  caused
by  the  presence  of  dissolved  sea  salt,  the  Gibbs  function  for
liquid  water  is  also  available  for  T  and  P  in  regions  extending ­
  somewhat  beyond  the  saturation  curve  and  beyond  the
melting  curve.
According  to  our  numerical  definition  of  liquid,  vapour
and  fluid  states,  the  initial  values  required  for  the  iteration  of
Eq.  (A3)  can  be  chosen  identically  for  the  fluid  density  in  the
supercritical  region  (T>Tc  or  P>Pc),  as  shown  in  Fig.  Al,
but  must  be  different  for  liquid  and  vapour  in  the  subcriticai
quarter  (T<Tq  and  P<Pq).  In  the  subcriticai  region,  separate ­
  Gibbs  functions  are  available  from  the  industrial  formulation ­
  IF-97  (IAPWS,  2007;  Wagner  and  Kretzschmar,  2008)

Fig.  A2.  Thermodynamic  relations  available  from  the  Industrial
Formulation  IF-97  (IAPWS,  2007;  Wagner  and  Kretzschmar,  2008)
defined  in  different  temperature-pressure  regions,  derived  with  reduced ­
  accuracy  from  the  IAPWS-95  Helmholtz  function  for  different ­
  independent  variables.  Here  we  make  use  of  the  Gibbs  functions ­
  “g(p,  T)"  available  in  region  1  (liquid/fluid)  and  in  region  2
(vapour/fluid)  as  shown  in  Fig.  Al.  In  region  3,  separate  equations
for  the  specific  volume  are  available  for  various  subregions  which
are  not  used  here.  Region  4  is  the  saturation  curve.  Graphics  reproduced ­
  from  IAPWS  (2007),  with  permission  of  IAPWS.
in  regions  1  and  2  (Fig.  A2)  as  defined  therein  which  provide ­
  excellent  starting  values  for  the  liquid  and  the  vapour
state.  These  Gibbs  functions  can  also  be  used  for  the  fluid,
region  1  below  623.15  K  and  100  MPa,  and  region  2  between
273.15  K  and  1073.15  K,  and  below  16.529  MPa.  In  the  sublimation ­
  region  and  in  the  supercritical  region,  the  ideal-gas
density,  p=P/(RifjT),  provides  a  sufficient  starting  estimate
below  273.15  K  and  above  650  K,  and  a  constant  value  of
p=1000kgm -3  can  be  used  below  650K,  Fig.  Al.  These
latter  choices  are  sufficient  to  ensure  numerical  convergence
but  do  not  necessarily  optimize  the  speed  of  the  code.  Additional ­
  considerations  apply  to  the  immediate  neighbourhood
of  the  critical  point  as  discussed  below.  Note  that  all  of  these
rules  are  built  into  the  library  routines  discussed  in  Part  2
(Wright  et  al.,  2010a)  so  that  the  user  can  make  use  of  the
routines  without  dealing  with  (or  even  being  fully  aware  of)
the  details.
The  critical  region  is  defined  here  as  the  T  —  P  rectangle
623.15-650K  and  16.529-35  MPa,  Fig.  Al.  The  coefficients
of  an  auxiliary  cubic  polynomial  equation  of  state

have  been  determined  by  regression  to  IAPWS-95  data
points  in  the  stable  liquid,  vapour  and  fluid  region  with  an
r.m.s.  deviation  of  1%  or  less  for  each  phase;  the  resulting
coefficients  are  given  in  Table  Al.  The  cubic  polynomial
used  for  Eq.  (A4)  permits  analytical  inversion  to  determine
p  (T.  p)  for  both  the  liquid  and  the  vapour  branches.  The
critical  point  of  Eq.  (A4)  was  chosen  to  be  identical  with  the
            