32
Part B - Certificates and approval requirements
At the same time, the stability of the installation against collapse, including the machine, and the function
of both the safety system and the brake systems shall be tested. The items covered by periodical
inspections are specified in Table 1.
Assembly
Test item
Rotor blade
Damage to the surface, cracks, structural inconsistencies
of the blade body (inspection from a lifting platform
or climbing device: Visual assessment and inspection of
the structure using suitable processes (e.g. knocking,
ultrasound)). Tightening torque of screw connections.
Damage to the lightning protection equipment.
Driveline
Leaks, unusual noises, condition of the corrosion protection,
lubrication condition, tightening torque of screw
connections. Condition of the gear unit (oil sample if
necessary).
Nacelle and components that carry force
and torque
Corrosion, cracks, unusual noises, lubrication condition,
tightening torque of screw connections.
Hydraulic system, pneumatic system
Damage, leaks, corrosion, function.
Support structure (tower, underwater
structure, foundation)
Corrosion, cracks, tightening torques of screw connections,
unacceptable scouring, position.
Safety equipment, measuring sensors
and brake systems
Function checks, compliance with limit values, damage,
wear.
System control and electrotechnical components
including transformer, station
and switchgear
Connections, attachment, function, corrosion, contamination.
Documents
Completeness, compliance with regulations, implementation,
test documents, regular undertaking of
maintenance, undertaking of any modifications/repairs
according to authorisation.
Table 1 :
Recurrent test items