Part B - Verifications and approval requirements
23
Phase
Objectives
Chapter
Appointed inspector
Approval authority
Development
Compilation of the site-
specific data
Determination of the
design basis
Preliminary design
1
1.3.2
2.2
3.2
4.2
Verification report and certificate
of conformity
Plausibility check*
Preliminary design
approval
(1 st release, poss. incl.
special measures)
Design
Final specification of
the subsoil model for
each offshore wind tur
bine site and the off
shore station
More detailed specifica
tion of the design basis
1.3.3
2.3
3.3
4.3
Verification report and certificate
of conformity
Plausibility check*
Design approval
(2 nd release, poss. incl.
special measures)
Final design of the pri
mary and secondary
support structures
Verification report and certificate
of conformity
Installation, operation
and decommissioning
planning
Verification report and certificate
of conformity
Plausibility check*
Implementation appro
val (3 rd release, poss.
incl. special measures)
Implementa-
tion
Production
1.3.4
2.4
3.4
4.4
Inspection reports and certificate
of conformity pertaining to the
monitoring of the production
phase
Plausibility check*
Operating release
(poss. incl. special
measures)
Transport
Inspection reports and certificate
of conformity pertaining to the
monitoring of the transport phase
Erection / installation
Inspection reports and certificate
of conformity pertaining to the
monitoring of the erection/instal
lation phase
Commissioning
Inspection reports and certificate
of conformity pertaining to the
monitoring of the commissioning
phase
As-built drawing,
Operations manual,
Test and inspection
plan for periodic ins
pections
Verification reports pertaining to
the as-built drawing, operations
manual and test and inspection
plan for periodic inspections
Project certificate
Operation
Operation, maintenance
and monitoring
1.3.4
2.5
3.5 4.5
Periodic inspections verification
report and certificate of conformity
Plausibility check*
Maintenance or tem
porary revocation of the
operating permit
Decommis-
sioning
Decommissioning
planning
1.3.6
2.6
3.6
4.6
Verification report and certificate
of conformity pertaining to the
decommissioning plan
Plausibility check*
Decommissioning re
lease (poss. subject to
specific requirements)
Carrying out
decommissioning
Inspection reports and certificate
of conformity pertaining to the
decommissioning phase
Plausibility check*
and declaration stating
that the measures have
been completed
Table 1 -1 : Timescale for offshore wind turbines
Plausibility check carried out by the BSH, together with the BAM and BAW, and possibly a specially appointed
inspector.