Object : Oil Spill Identification - Round Robin 2005

24  Oil  Spill  identification  -  Round  Robin  20045

Oil  spill  identification  samples  from  inland  waters  and  the  North  Sea  are
analyzed  according  the  concept  guideline  Part  2  of  CEN  BT/TF  120.

In  general:  Samples  are  analyzed  in  duplicate  with  GC-FID.  After
assessment  of  the  results  the  (probably)  matching  samples  are  also
analyzed  with  GC-MS  in  SIM  mode.
After  a  visual  assessment  of  the  chromatograms  (probably)  matching
samples  are  integrated  for  a  large  range  of  compounds  (depending  on
the  type  of  oil  and  compounds  available).  Ratios  between  spill  and
source  samples  are  compared  by  using  the  repeatability  limit  (ISO
5725)  as  a  match  criterion.

=>

Extract  I
match
non-match

Extract  II
match
non-match

Source  I
Source  II

Notes/remarks:
RIZA  has  diluted  the  Sintef  mixture  for  peak  recognition  a  factor  of  3
with  DCM  and  has  analyzed  the  diluted  mixture  8  times  in  order  to
calculate  the  RSD  for  the  mixture  at  the  given  concentration.
The  results  can  be  found  on  the  CD  in  file  St  Sintef  ratio  validation.xls.
In  the  guideline  it  is  stated  that  the  RSD  should  be  equal  or  lower  than
5%  during  validation  of  the  method.  This  is  valid  for  all  ratios  with  the
ratio  DR-30d/30ab  at  limit.
2.10  Sintef
Contacts:  K.R.  Sorheim,  L-G.  Faksness  and  P.S.  Daling.
Sintef  http://www.sintef.no/  is  a  large  Norwegian  engineering  institute
and  is  among  others  active  in  the  petroleum  industry  and  petroleum
research.  Sintef  analyzes  all  oil  spill  samples  for  the  Norwegian
government.
As  a  basis  for  this  oil  spill  fingerprinting  case,  SINTEF  has  used  the
presently  draft  version,  August  2005,  of  the  "CEN/BT/TaskForce  120
Oil  Spill  Identification":  Part  2  Analytical  methodology  and
interpretation  of  results"
Sintef  analyzed  the  RR-samples  with  GC-FID  and  with  GC-MS  in  SIM
mode  on  PAH's  and  biomarkers.  The  resulting  chromatograms  are  first
evaluated  visually  and  when  a  possible  match  is  assumed  a  series  of
ratios  are  statistically  compared.
=>  Extract  I  and  II:  Positive  match  between  the  spill  samples.
The  spill  samples  are  from  the  same  source
Source  I:  Positive  match  to  the  spills  (Extract  I  and  Extract  II)
Source  II:  Non-match  to  the  spills  (Extract  I  and  Extract  II)
            