Table 82 shows the relevant MS parameters for the target compounds and their internal
standards (ISTD).
Table 82: Parameters of the target substances: molecular weight (MW), retention time (RT; GC
conditions see above) and masses used for analysis in SIM mode (m/z)
T arget-substances/
Internal standards
MW
RT
El-Modus
GC-MS (m/z)
NCI-Modus
Di 4 -Trifluralin
349
24.77
267, 315
349, 319
Trifluralin
335
24.93
264, 306
335, 305
Chlorpyriphos-methyl
321
28.83
288, 286
212, 141
D io-Chlorpyriphos-ethyl
359
30.46
326, 324
322
Chlorpyriphos-ethyl
349
30.59
315, 199
313
D 4 -Endosulfan I
408
32.75
237, 272
376, 410
Endosulfan I
404
32.82
241, 265
406, 372
Endosulfan II
404
34.73
241, 265
406, 370
6.6.3 Procedure for the analysis of Chlorpyrifos, Endosulfan and
Trifluralin in water
Water samples were taken at 5 m water depth using a 10 L glass bowl. Prior to solid
phase extraction (SPE), the samples were acidified to pH 2.5-3.0 (25 % hydrochloric
acid, p. a.). Di4-Trifluralin, Dio-Chlorpyrifos-ethyl, and D4-Endosulfan I (Dr. Ehrens-
dorfer GmbH) were added as internal standards (e.g. 0.4 ng/L). The seawater was
pumped through a column filled with 2 g Chromafix HR-P resin (Macherey and Nagel,
Diiren) in a custom made extraction system. The loaded columns were dried and stored
in the dark at 8°C until elution. All target substances were eluted with 100 ml
dichloromethane in the opposite direction of sampling. After solvent change to hexane,
the extracts were concentrated to 300 pi and analysed by GC-MS (see 6.6.2).